Small Ducts & Rooftop Unit Controls

oac Series

Thermal Dispersion Airflow/Temperature Measurement Devices (ATMD) for Outdoor Airflow Control (OAC)

GreenTrol’s OAC Series Outdoor Airflow and Temperature Controllers deliver precision control for rooftop air handlers, ducted outdoor air intakes, and systems without an airside economizer. Designed for flexibility and energy efficiency, these controllers optimize ventilation and improve indoor air quality in fan coils, DOAS, and makeup air systems.

With adjustable direct, standoff, or insertion mount probes, the OAC Series supports demand-controlled ventilation (DCV) using CO2 sensors or occupancy counters.

Each controller ensures compliance with ASHRAE and LEED standards while compensating for damper hysteresis, filter loading, wind, and fan speed variations. Easy to configure and integrate with building automation systems, OAC controllers deliver unmatched performance for maintaining outdoor airflow setpoints, providing continuous verification, and improving comfort and energy efficiency.

Model

Measurement

Application

Probe Sizes

Remote Transmitter

Alarm

Connectivity

Airflow,

Temperature

Rooftop OA Hoods and Intakes

(≤ 8 ft2 opening)

-US: Universal Standoff

6", 8", or 16"

Analog Control Signal

BACnet MS/TP

Airflow,

Temperature

Square Ducts

(≤ 8 ft2 opening)

-UI: Universal Insertion

6", 8", or 16"

Analog Control Signal

BACnet MS/TP

Airflow,

Temperature

Round Ducts

(4 to 16")

-DI: Duct Insertion

4 to 16"

Analog Control Signal

BACnet MS/TP

Airflow,

Temperature

Rooftop OA Hoods and Intakes

(≤ 8 ft2 opening)

-US: Universal Standoff

6", 8", or 16"

Analog Control Signal

BACnet MS/TP

Airflow,

Temperature

Square Ducts

(≤ 8 ft2 opening)

-UI: Universal Insertion

6", 8", or 16"

Analog Control Signal

BACnet MS/TP

Airflow,

Temperature

Round Ducts

(4 to 16")

-DI: Duct Insertion

4 to 16"

Analog Control Signal

BACnet MS/TP

Airflow,

Temperature

Rooftop OA Hoods and Intakes

(≤ 8 ft2 opening)

-US: Universal Standoff

6", 8", or 16"

BACnet MS/TP

MP-Bus Control Signal /Scheduler

Airflow,

Temperature

Square Ducts

(≤ 8 ft2 opening)

-UI: Universal Insertion

6", 8", or 16"

BACnet MS/TP

MP-Bus Control Signal /Scheduler

Airflow,

Temperature

Round Ducts

(4 to 16")

-DI: Duct Insertion

4 to 16"

BACnet MS/TP

MP-Bus Control Signal /Scheduler

Airflow,

Temperature

Rooftop OA Hoods and Intakes

(≤ 8 ft2 opening)

-US: Universal Standoff

6", 8", or 16"

BACnet MS/TP

MP-Bus Control Signal

Airflow,

Temperature

Square Ducts

(≤ 8 ft2 opening)

-UI: Universal Insertion

6", 8", or 16"

BACnet MS/TP

MP-Bus Control Signal

Airflow,

Temperature

Round Ducts

(4 to 16")

-DI: Duct Insertion

4 to 16"

BACnet MS/TP

MP-Bus Control Signal